ISPRA Istituto Superiore per la Ricerca e la Protezione Ambientale

.

.

.

space

26,400,778 VISITS SINCE 5/1/2011  1 CONNECTED USERS

space

.

.

National Tidegauge Network

General information

Networks

Tidegauge

Anomalus waves

Levelling

Stations

Ancona

Anzio

Bari

Cagliari

Carloforte

Catania

Civitavecchia

Crotone

Gaeta

Genova

Ginostra

Imperia

La Spezia

Lampedusa

Livorno

Marina di Campo

Messina

Napoli

Ortona

Otranto

Palermo

Palinuro

Ponza

Porto Empedocle

Porto Torres

Ravenna

Reggio Calabria

Salerno

San Benedetto del Tronto

Sciacca

Strombolicchio

Taranto

Tremiti

Trieste

Valona

Venezia

Vieste

Stations comparison

Sensors

Air temp. & rh% transducer

Barometric sensor

Hydrometric staff

Level pressure

Multi parameter probe

Radar level transducer

Ultrasonic tidegauge

Water level sensor

Water temperature transducer

Wind direction transducer

Wind speed transducer

space

space

LEVEL PRESSURE SENSOR - TLP

A submergible pressure sensor for accurate measurement of water level. The hydrostatic weight produce an over pressure (respect to the atmospheric pressure) and the transducer converts the pressure in an electrical signal corresponding to the water level.
The sensor is based on a silicon sensing element and a relevant electronics which includes a temperature compensation. Both are enclosed in a water proof titanium case. It is integrated with a special cable (shield and provided by a nylon vent tube for atmospheric pressure compensation) moulded to the sensor body for a water-tight connection.
The distance between the sensor and the data acquisition unit can be up to 1 km.
The sensor shall be submerged under the minimum water level foreseen, and agree the kind of water body to be measured.
The sensor can be fixed over vertical wall, slope walls or at river bed.
All sensors have a signal output 420 mA.

Technical data

Range: 010m, 015m, 020m, 030m, 050m
Accuracy / Linarity: SLPXXA: 0,25% f.s. ; SLPXXB: 0,1% f.s.
Signal Output: 420 mA
Compensated temperature range: -10 C +60C
Operatine Temperature: -20 C +80 C

LEVEL PRESSURE SENSOR

This sensor is installed into these stations:

Ginostra, Strombolicchio